Deep Learning-Based Localization and Detection of Malpositioned Endotracheal Tube on Portable Supine Chest Radiographs in Intensive and Emergency Medicine: A Multicenter Retrospective Study.

Researchers

Journal

Modalities

Models

Abstract

We aimed to develop a computer-aided detection (CAD) system to localize and detect the malposition of endotracheal tubes (ETTs) on portable supine chest radiographs (CXRs).This was a retrospective diagnostic study. DeepLabv3+ with ResNeSt50 backbone and DenseNet121 served as the model architecture for segmentation and classification tasks, respectively.Multicenter study.For the training dataset, images meeting the following inclusion criteria were included: 1) patient age greater than or equal to 20 years; 2) portable supine CXR; 3) examination in emergency departments or ICUs; and 4) examination between 2015 and 2019 at National Taiwan University Hospital (NTUH) (NTUH-1519 dataset: 5,767 images). The derived CAD system was tested on images from chronologically (examination during 2020 at NTUH, NTUH-20 dataset: 955 images) or geographically (examination between 2015 and 2020 at NTUH Yunlin Branch [YB], NTUH-YB dataset: 656 images) different datasets. All CXRs were annotated with pixel-level labels of ETT and with image-level labels of ETT presence and malposition.None.For the segmentation model, the Dice coefficients indicated that ETT would be delineated accurately (NTUH-20: 0.854; 95% CI, 0.824-0.881 and NTUH-YB: 0.839; 95% CI, 0.820-0.857). For the classification model, the presence of ETT could be accurately detected with high accuracy (area under the receiver operating characteristic curve [AUC]: NTUH-20, 1.000; 95% CI, 0.999-1.000 and NTUH-YB: 0.994; 95% CI, 0.984-1.000). Furthermore, among those images with ETT, ETT malposition could be detected with high accuracy (AUC: NTUH-20, 0.847; 95% CI, 0.671-0.980 and NTUH-YB, 0.734; 95% CI, 0.630-0.833), especially for endobronchial intubation (AUC: NTUH-20, 0.991; 95% CI, 0.969-1.000 and NTUH-YB, 0.966; 95% CI, 0.933-0.991).The derived CAD system could localize ETT and detect ETT malposition with excellent performance, especially for endobronchial intubation, and with favorable potential for external generalizability.Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Society of Critical Care Medicine and Wolters Kluwer Health, Inc.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *