A deep learning method for translating 3D-CT to SPECT ventilation imaging: First comparison with Kr-gas SPECT ventilation imaging.

Researchers

Journal

Modalities

Models

Abstract

This study aimed to evaluate the accuracy of deep learning (DL)-based computed tomography (CT) ventilation imaging (CTVI).A total of 71 cases who underwent single-photon emission CT 81m Kr-gas ventilation (SPECT V) and CT imaging were included. Sixty cases were assigned to the training and validation sets and the remaining 11 cases were assigned to the test set. To directly transform 3DCT (free-breathing CT) images to SPECT V images, a DL-based model was implemented based on the U-Net architecture. The input and output data were 3DCT- and SPECT V-masked, respectively, except for whole-lung volumes. These data were rearranged in voxel size, registered rigidly, cropped, and normalized in pre-processing. In addition to a standard estimation method (i.e., without dropout during the estimation process), a Monte-Carlo Dropout (MCD) method (i.e., with dropout during the estimation process) was used to calculate prediction uncertainty. To evaluate the two models’ (CTVIMCD U-Net , CTVIU-Net ) performance, we used five-fold cross-validation for the training and validation sets. To test the final model performances for both approaches, we applied the test set to each trained model and averaged the test prediction results from the five trained models to acquire the mean test result (bagging) for each approach. For the MCD method, the models were predicted repeatedly (sample size = 200), and the average and standard deviation maps were calculated in each voxel from the predicted results: the average maps were defined as test prediction results in each fold. As an evaluation index, the voxel-wise Spearman rank correlation coefficient (Spearman rs ) and dice similarity coefficient (DSC) were calculated. The DSC was calculated for three functional regions (high, moderate, and low) separated by an almost equal volume. The coefficient of variation was defined as prediction uncertainty, and these average values were calculated within three functional regions. The Wilcoxon signed-rank test was used to test for a significant difference between the two DL-based approaches RESULTS: The average indexes with one standard deviation (1SD) between CTVIMCD U-Net and SPECT V were 0.76 ± 0.06, 0.69 ± 0.07, 0.51 ± 0.06, and 0.75 ± 0.04 for Spearman rs , DSChigh , DSCmoderate , and DSClow , respectively. The average indexes with 1SD between CTVIU-Net and SPECT V were 0.72 ± 0.05, 0.66 ± 0.04, 0.48 ± 0.04, and 0.74 ± 0.06 for Spearman rs , DSChigh , DSCmoderate , and DSClow , respectively. These indexes between CTVIMCD U-Net and CTVIU-Net showed no significance difference (Spearman rs , p = 0.175; DSChigh , p = 0.123; DSCmoderate , p = 0.278; DSClow , p = 0.520). The average coefficient of variations with 1SD were 0.27 ± 0.00, 0.27 ± 0.01, and 0.36 ± 0.03 for the high-, moderate-, and low-functional regions, respectively, and the low-functional region showed a tendency to exhibit larger uncertainties than the others.We evaluated DL-based framework for estimating lung-functional ventilation images only from CT images. The results indicated that the DL-based approach could potentially be used for lung-ventilation estimation. This article is protected by copyright. All rights reserved.This article is protected by copyright. All rights reserved.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *