Cross-Cohort Automatic Knee MRI Segmentation With Multi-Planar U-Nets.

Researchers

Journal

Modalities

Models

Abstract

Segmentation of medical image volumes is a time-consuming manual task. Automatic tools are often tailored toward specific patient cohorts, and it is unclear how they behave in other clinical settings.To evaluate the performance of the open-source Multi-Planar U-Net (MPUnet), the validated Knee Imaging Quantification (KIQ) framework, and a state-of-the-art two-dimensional (2D) U-Net architecture on three clinical cohorts without extensive adaptation of the algorithms.Retrospective cohort study.A total of 253 subjects (146 females, 107 males, ages 57 ± 12 years) from three knee osteoarthritis (OA) studies (Center for Clinical and Basic Research [CCBR], Osteoarthritis Initiative [OAI], and Prevention of OA in Overweight Females [PROOF]) with varying demographics and OA severity (64/37/24/53/2 scans of Kellgren and Lawrence [KL] grades 0-4).0.18 T, 1.0 T/1.5 T, and 3 T sagittal three-dimensional fast-spin echo T1w and dual-echo steady-state sequences.All models were fit without tuning to knee magnetic resonance imaging (MRI) scans with manual segmentations from three clinical cohorts. All models were evaluated across KL grades.Segmentation performance differences as measured by Dice coefficients were tested with paired, two-sided Wilcoxon signed-rank statistics with significance threshold α = 0.05.The MPUnet performed superior or equal to KIQ and 2D U-Net on all compartments across three cohorts. Mean Dice overlap was significantly higher for MPUnet compared to KIQ and U-Net on CCBR ( 0.83 ± 0.04 vs. 0.81 ± 0.06 and 0.82 ± 0.05 ), significantly higher than KIQ and U-Net OAI ( 0.86 ± 0.03 vs. 0.84 ± 0.04 and 0.85 ± 0.03 ) , and not significantly different from KIQ while significantly higher than 2D U-Net on PROOF ( 0.78 ± 0.07 vs. 0.77 ± 0.07 , P = 0.10 , and 0.73 ± 0.07 ) . The MPUnet performed significantly better on N = 22 KL grade 3 CCBR scans with 0.78 ± 0.06 vs. 0.75 ± 0.08 for KIQ and 0.76 ± 0.06 for 2D U-Net.The MPUnet matched or exceeded the performance of state-of-the-art knee MRI segmentation models across cohorts of variable sequences and patient demographics. The MPUnet required no manual tuning making it both accurate and easy-to-use.3 TECHNICAL EFFICACY: Stage 2.© 2021 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *