A motion-corrected deep-learning reconstruction framework for accelerating whole-heart MRI in patients with congenital heart disease.

Researchers

Journal

Modalities

Models

Abstract

MRI is an important imaging modality for the assessment and management of adult patients with congenital heart disease (CHD). However, conventional techniques for 3D whole-heart acquisition involve long and unpredictable scan times and methods that accelerate scans via k-space undersampling often rely on long iterative reconstructions. Deep-learning-based reconstruction methods have recently attracted much interest due to their capacity to provide fast reconstructions whilst often outperforming existing state-of-the-art methods. In this study, we sought to adapt and validate a non-rigid motion-corrected model-based deep-learning (MoCo-MoDL) reconstruction framework for 3D whole-heart MRI in a CHD patient cohort.The previously proposed deep-learning reconstruction framework MoCo-MoDL, which incorporates a non-rigid motion-estimation network and a denoising regularisation network within an unrolled iterative reconstruction, was trained in an end-to-end manner using 39 CHD patient datasets. Once trained, the framework was evaluated in 8 CHD patient datasets acquired with seven-fold prospective undersampling. Reconstruction quality was compared with the state-of-the-art non-rigid motion-corrected patch-based low-rank reconstruction method (NR-PROST) and against reference images (acquired with three-or-four-fold undersampling and reconstructed with NR-PROST).Seven-fold undersampled scan times were 2.1 ± 0.3 minutes and reconstruction times were  ~ 30 seconds, approximately 240 times faster than an NR-PROST reconstruction. Image quality comparable to the reference images was achieved using the proposed MoCo-MoDL framework, with no statistically significant differences found in any of the assessed quantitative or qualitative image quality measures. Additionally, expert image quality scores indicated the MoCo-MoDL reconstructions were consistently of a higher quality than the NR-PROST reconstructions of the same data, with the differences in 12 of the 22 scores measured for individual vascular structures found to be statistically significant.The MoCo-MoDL framework was applied to an adult CHD patient cohort, achieving good quality 3D whole-heart images from  ~ 2-minute scans with reconstruction times of  ~ 30 seconds.Copyright © 2024. Published by Elsevier Inc.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *